1.
Int J Oral Maxillofac Implants ; 0(0): 1-29, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38717354

RESUMEN

PURPOSE: One-size implant-abutment (OSIA) connection systems have been developed for simplicity of clinical use and for a range of implant diameters. The aim of this in vitro study was to investigate the rotational load fatigue performance of different implant diameters and abutment platforms of an OSIA connection system. METHODOLOGY: Narrow, regular and wide diameter implants were tested with Regular Base (RB/WB) abutments of an OSIA system (Straumann. BLX). Wide diameter implants were also tested with Wide Base (WB) abutments. This resulted in 4 test groups (n=5): N-RB/WB (Narrow, 3.5mm, RB/WB abutment), R-RB/WB (Regular, 4.0mm, RB/WB abutment), W-RB/WB (Wide, 5.0mm, RB/WB abutment) and W-WB (Wide, 5.0mm, WB abutment). A rotational load fatigue machine applied a sinusoidally varying stress at an angle of 45o, producing an effective bending moment of 35Ncm at a frequency of 10 Hz in air at 20 oC. The number of cycles to failure was recorded. Results were evaluated using ANOVA. Failed specimens were examined with SEM to evaluate the failure mode. Pristine specimens were sectioned to examine the implant-abutment connection. RESULTS: All specimens in the 3 test groups with RB/WB abutments failed within the range of 558,750 cycles to 4,497,619 cycles, while the W-WB test group reached the upper limit of 5 million cycles without failure. Significant difference was found between abutment platforms (P < .001). There were no significant differences found for implant diameters (P =.857). However, with increasing implant diameter, implant fracture was less common and the location of failure was more coronal and consistently at the level of the implant platform for the abutment, and at the screw neck. CONCLUSIONS: For wide diameter implants, WB abutments exhibited a superior fatigue performance than RB/WB abutments, and would be preferred in situations of high mechanical risk. Increasing implant diameter, when used with RB/WB abutments, did not improve fatigue performance due to the one-size prosthetic connection, but failures were less catastrophic, and coronally located, which may be advantageous in managing failures.

2.
Int J Oral Maxillofac Implants ; 39(1): 119-126, 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38416005

RESUMEN

PURPOSE: This in vitro study investigated the effect of implant geometry and diameter on the rotational load fatigue performance of an implant system with an internal conical connection with microthreads. MATERIALS AND METHODS: Regular (4.2 mm) and wide-diameter (4.8 mm) Astra Tech EV implants with straight (S) and conical (C) geometries were tested with their corresponding titanium abutments, comprising four test groups: 4.2-mm S (Group 1), 4.2-mm C (Group 2), 4.8-mm S (Group 3), and 4.8-mm C (Group 4). Five samples were included in each group. Customized brass implant holders and abutment holders were machined. A rotational load fatigue machine was used to apply a sinusoidally varying load to the implant-abutment interface at an angle of 45 degrees to produce an effective bending moment of 35 Ncm at a frequency of 14 Hz (air temperature: 20°C). The number of cycles to failure was recorded, with the upper limit set at 5 × 106 cycles. Results were analyzed using ANOVA. Failed samples were examined with a scanning electron microscope to evaluate the mode of failure. RESULTS: Of the 20 total samples, 2 failed, with Groups 1 and 2 each reporting one failure. Abutment and abutment screw fracture were observed in the failed sample in Group 1, while implant and abutment screw fracture occurred in the failed sample in Group 2. All wide-diameter implants ran beyond the cut-off without failure, but abutment screw loosening was noted in one sample in Group 3. No significant difference was found between implant groups of different geometries and diameters. Damage to the abutments and the implant internal surface were noted in all failed samples. CONCLUSIONS: While no significant differences were found between the test groups, failures were observed only in the regular-diameter group. The abutment and abutment screw fractured deep within the implant, and the implant fractured below the simulated bone level. These modes of failure may pose a significant clinical challenge during retrieval of these components.


Asunto(s)
Implantes Dentales , Falla de Equipo , Ensayo de Materiales , Proyectos de Investigación , Temperatura , Titanio